Steam turbine:
manufacturer: Murray (Dresser-Rand)
rating: 9500 kW
rating with zero extraction: 6500 kW
inlet steam: 850 PSIG/750 deg F
extraction steam: 125 PSIG
extraction steam flow: 0 to 50,000 lb/hr
maximum inlet steam flow: 120,000 lbs/hr
maximum exhaust flow: 75,000 lbs/hr
number of stages: 9
speed: 4711 rpm
inlet steam flange: 6" side
exhaust flange: 48" top
control: Woodward 505E
gear reducer Lufkin 4700 to 1800 rpm
generator:
manufacturer: ideal
rating: 11177 kVA
kW: 9500
pf: 0.85
type: Tewac
exciter: brushless 25 kW.
Year built: 2001
last year run: 2008
scope of supply
steam turbine generator skid
Lube oil system,
condenser,
air ejector and turbine control panel.
Excluded: cooling tower, gen control panel and breakers