Manufacturer: Dresser-Rand Type RD6M2 Steam Turbine
Rating: 6,600 kW
Inlet steam: 600 psig / 750 °F
Exhaust steam: 3" HGA
Steam rate: 10.38 lbs/kWh
Speed: 5,361 rpm
Turbine rotation: clockwise (viewed from governor end)
Gear reducer:
Manufacturer: Lufkin
Rating: 9,215 hp
Speed: 5,361 / 1,800 rpm
Manufacturer: GEC Alsthom
Rating: 7,765 kVA
Voltage: 6,900 V / 3 phase, 60 Hz, 0.85 pf
Type: air cooled
Scope of supply:
- Steam turbine with gear reducer mounted on one skid
- Generator with brushless exciter
- Turbine inlet trip valve
- Air-cooled condenser designed for 58,260 lbs/hr
- Turbine control panel
- Generator control panel
- Woodward 505 governor panel
- Lube oil system
- Spare parts, manuals and drawings
Year built: 1995, shutdown 2011